Learning center

Fourier Transform & Spectrum Analysis

Understand frequency components, spectral bins, and normalization.

SCIENTIFIC METHOD REFERENCE

The discrete Fourier transform represents a sampled signal using complex frequency components. FFT algorithms compute this transform efficiently.

Mathematical principle

X[k] = ∑n=0N−1 x[n] e−i2πkn/N

x[n] is the sampled signal; N is its length; k identifies a frequency bin.

Input definitions

ItemMeaning
SamplesValues in a defined order and unit.
Sampling rateSamples per second, used to label frequency.
Transform lengthFor an N-point transform, bin spacing is fₛ/N.

Analysis choices

ItemMeaning
WindowChanges leakage and amplitude scaling.
NormalizationSpecify amplitude, power, or power spectral density.
Spectrum rangeDistinguish one-sided and two-sided representations.

Worked mathematical figure

Sampled signal
010.40.60.80.21.2-0.21.6-0.62-1Time (s)Amplitude (a.u.)
One-sided amplitude spectrum
0150.8100.6150.4200.2250Frequency (Hz)Amplitude (a.u.)5 Hz12 Hz
Synthetic example: 5 Hz and 12 Hz components; 100 samples/s; 200 samples; rectangular window. This figure was calculated for the website.

Interpretation

A peak identifies a frequency component in the analyzed segment. Zero padding samples the spectrum more densely; it does not add information to the original recording. Preserve the window and normalization when comparing spectra.

Scientific references

Scientific background. Available algorithms, defaults, and settings are defined by the Pop Lab app and release.

From the principle to a scoped workflow

Before using a spectrum, identify its input domain, normalization and units. The same frequency axis can accompany different measured quantities; a visually similar peak does not make amplitude and density interchangeable.

Learning pathWhat to inspect and what it establishes
Full-record FFT amplitude and segmented Welch density

The CWRU guide separates the full-record amplitude spectrum from the Welch density table, and retains the sampling rate, window, detrending and complete exported rows.

Evidence scope: One named bearing-recording workflow; it does not establish every spectral estimator, other sensors or fault diagnosis.

Complex FID, frequency coordinates and ppm

The spectroscopy guide follows a selected complex FID through FFT and ppm coordinates, distinguishing plotted axis direction from saved numeric order.

Evidence scope: One synthetic four-voxel input with one selected voxel; it is not chemical identification, metabolite quantification or general spectral validation.

Watch the scientific explanation

24-second educational animation with synthetic data. No audio; captions and transcript available. Download MP4Video and transcript
Read the video transcript

0:00 Inspect a two-second waveform, sampled at 100 samples per second. It is the sum of a 5 Hz component with amplitude 0.7 and a 12 Hz component with amplitude 0.3.

0:08 The discrete Fourier transform separates the frequency components. The one-sided amplitude spectrum uses the same 200 samples, with interior coefficients scaled by 2/N.

0:16 Two peaks appear at 5 Hz and 12 Hz. Their amplitudes match the known inputs because both components complete an integer number of cycles in the record.

Read the worked example and download data

Worked examples describe particular inputs, methods and recorded results. Check current availability and input requirements before planning an evaluation.

← Back to the learning center